DeckPlanner
Home/Lumber/Fasteners

Deck fastener guide

Fasteners are the cheapest part of a deck and the most common cause of its failure. The two things that go wrong are galvanic corrosion, where two dissimilar metals eat each other in the presence of treated wood and water, and using a screw where the hardware specifies a nail.

Corrosion is a chemistry problem, not a quality problem

Modern pressure treatment is copper-based — ACQ, CA and the older CCA all rely on copper as the biocide. Copper is cathodic to zinc and to steel, so when a zinc-coated screw sits in wet treated wood, the zinc becomes the sacrificial anode and dissolves. The screw loses its coating, then its shank, and the deck board comes loose. Higher copper retention in ground-contact lumber accelerates it.

Fastener coatingWorks withDo not use with
Electro-galvanisedInterior, untreated wood onlyAny treated lumber, any exterior use
Hot-dip galvanised (ASTM A153)Treated lumber above groundGround contact, cedar, ipe, coastal air
Stainless 304Cedar, redwood, most treated lumberCoastal salt air, ipe (staining risk)
Stainless 316Everything, including coastal and ipeNothing — it is the safe default where budget allows
Ceramic / epoxy coatedTreated lumber, most compositesCheck the coating's listed compatibility
AluminiumUntreated dry woodTreated lumber — rapidly corrodes

Two rules follow from the table. Anything touching treated lumber needs at least hot-dip galvanised, and anything in ground contact or within a mile of salt water needs stainless. Where a stainless screw touches galvanised hardware, the stainless wins and the galvanised part corrodes — which is why you do not mix them in the same connection.

Length is a penetration question

The working rule for decking is that the fastener must penetrate the joist by at least 1″ after passing through the board. For a 1″ deck board that means a 2″ screw; for 5/4×6 at 1″ thick, a 2″ or 2½″ screw. Too short and the screw holds by the tip in the top fibres of the joist; too long and it exits the bottom of a 2×8 and creates a rust path.

For structural connections the rule changes: hangers, ties and post bases are tested with specific fasteners, and substituting a deck screw for a hanger nail voids the load rating. Hanger nails are hardened and have a full-diameter shank; deck screws are hardened differently and are brittle in shear.

How many fasteners a deck consumes

ConnectionBasisPer 100 sq ft
Face screws, 16″ joists2 per board per joist crossing~350
Hidden clips1 per board per joist crossing~175
Joist hangers1 per joist end, 6–10 nails each~20 hangers
Ledger fasteners2 rows staggered, per fastener schedule~12
Guard post anchors2 per post, 4 fasteners each~8

The face-screw figure assumes 5.5″ boards with 16″ joist spacing; it scales linearly with both, which is why the board calculator computes it from the actual row and joist count rather than from area. Buy 10% spare, because dropped and stripped screws are normal and a partial box never finishes the job.

Where fasteners are the wrong answer entirely

Some connections should not be made with screws or nails at all: a ledger to a house band, a beam to a post, and a guard post to a frame. Those want structural screws or bolts with a published load value, or a manufactured connector. A 3″ deck screw has no published shear capacity, so using one in a structural connection is not a shortcut — it is an unrated connection.

What fastener counts do not solve

Questions people actually ask

Can I use regular deck screws in treated lumber?

Only if they are rated for it — coated or stainless. Plain electro-galvanised screws will corrode away in wet treated wood within a few years, and the failure is hidden under the board until it lets go.

Do I need stainless screws for cedar?

Yes, or a coating rated for cedar. Cedar contains acids that attack zinc, and bare steel leaves black iron stains that bleed into the wood and cannot be sanded out.

Can I use deck screws for joist hangers?

No. Hangers are rated with specific hardened nails or manufacturer-approved structural screws. A deck screw has a thinner shank and no published load value in that application.

How long should deck screws be?

Long enough to penetrate the joist by 1″ after passing through the board. For 1″ decking over a solid joist, that is a 2″ screw; for 2″ material, 2½–3″.

How many screws per deck board?

Two per joist crossing for a standard 5.5″ board, and two per crossing for wider boards as well. The count grows with joist density, not with board width, which is why 12″ joist spacing costs nearly twice the fasteners of 16″.

Related

More in Lumber

Related reading